Miriam Senne, Benjamin D. Killeen, Tony Danjun Wang, Nassir Navab

The authors develop a model that estimates visceral adipose tissue and body-fat percentage from clothing-tolerant millimeter-wave surface scans. It combines synthetic point clouds from clinical scans and posed body models in a shared, three-head model. In a 14-person pilot, multi-head body-fat predictions had higher correlation with bioimpedance than the single-head baseline, 0.937 versus 0.868; this measures association, not accuracy.