Diogo J. Paulo, Hugo Proença, João C. Neves

The authors test whether single-image morph attack detectors trained on digital images generalize to printed-and-scanned images. They evaluate eight detectors on paired digital and print-scan versions of SYN-MAD22, without adapting the detectors. Mean equal error rate rises from 11.00% digitally to 41.85% at 600 DPI and 41.72% at 300 DPI, under the tested acquisition setups.